Skip to Main Content
Home
Returns
About Us
Contact Us
Cart
Shopping Cart
Log In
My Account
My Account
My Account
Menu
home
Menu
Toggle navigation
Questions?
Call Us
7749014770
Search
Search
Air Cleaners
Duct Mounted
Return Grille
Ceiling Mount
Portable
Cell Washing
Media Filters
Aprilaire
Honeywell
Trion
Field Controls
Humidifiers
Evaporative & Fan Powered
Steam Powered
Self-Contained
Accessories
Ultra-Violet
RGF
Honeywell
Field Controls
PremierOne
HVAC Supplies
Heating Supplies & Parts
Furnace Filters
Pedestal Fan Air Filter
Ventilation
Permatron
Home
HVAC Supplies
Heating Supplies & Parts
QwikConnect™ QT6110 ECM Adapter
QwikConnect™ QT6110 ECM Adapter
0
Review(s)
0
0
5
Write a Review
Your Price:
$87.67
Questions about this item? Be the first to ask here.
Part Number:
QT6110
Put me on the Waiting List
Quantity
+
-
Add to Cart
Description
QwikConnect™ ECM Adapter for replacing ECM 2.3 or Eon Motors in fan coil units to Evergreen® CM or ECM motors. Used with QwikSwap V3 (QT6104).
On one end of this adapter, there are two plugs (J1 for power and J2 for communications) that are meant to be plugged into an ECM 2.3 or Eon motor. For the Evergreen® Motor, the signals from J1 and J2 are connected to the proper plugs (P1 for Power, P2 for Communications).
Connect the QwikConnect to the Evergreen's PWM input solely (speed tap 1) in order to use all of the speeds available. The Evergreen will be able to adjust its speed automatically as a result. Connect the QwikConnect to speed tap 3 or 5 if you only want to run the motor at one speed.
Installation Instructions
Using a PWM motor speed control, a 16-pin communications connector, and a 5-pin power connector, confirm that the faulty motor is an ECM 2.3 or Eon motor.
Ascertain the horsepower, rotational direction, and operational voltage of the malfunctioning motor.
The appropriate Evergreen EM (115, 208, or 230 VAC) or CM (208, 230, 277 VAC) motor should be purchased to match the horsepower, rotational direction, and voltage. Install the substitute motor.
Connect the wiring harness of the malfunctioning motor to the J1 and J2 connections of the QwikConnectTM ECM Adapter cable after removing it from the motor.
Insert the QwikConnectTM ECM Adaptor cable's P1 and P2 plugs into the Evergreen EM or CM motor replacement.
Verify proper operation.
Adapter Instructions
QwikSwap V3 Data Sheet
QwikSwap Application Chart
QwikProducts Catalog
Recently Viewed Items
Turn History Off
[history_item_name]
[ITEMPRICE]
[ITEMPRICE]
[ITEMSALEPRICE]
Sale
Clear
×
Mailing List
Subscribe
Unsubscribe
Ooop!
The email you entered isn't valid.
WooHoo!
You subscribed successfully.
Ok!
You're unsubscribed.
TOP
Categories
Menu Links
Contact Us
[email protected]
7749014770
0
Items
×
Store Search