Trion 441729-101
Collector Cell Assembly for Trion HE2000 12½x20
Price:$208.00
  16 x 25 20 x 20 20 x 25

Trion Collector Cell Assembly for HE2000. Size 20 x 12½ x 5 inch. Genuine Trion electronic air cleaner cell. Note, Trion 20 x 25 inch air cleaners use two cells. Assembled with (13) 220110-029 ionizing wires and ready to slide in and use.

Trion cells are symmetrical so they can be used with air flow going right or left. The cell is simply flipped around for the opposite air flow. Depending on the air flow direction, the handle may need to be moved to the end that is facing out.

The Trion cells have a 17 gauge aluminum frame with 25 gauge aluminum plates.

Collector Cell Washing

collector cell dirt on platesWe recommend soaking the collector cells. Soaking cleans better than the dishwasher and cleans better than a pressure washer. The cells typically do not need to be cleaned as often as the prefilters.

After cleaning, inspect the cell plates for dirt, hold the cell up to light. View the plates through the ionizing section to see the dirtiest side. Note that only every other plate captures dirt.

The plates are either charged or grounded. The charged particles are attracted to the grounded plates and repelled by the charged plates. Closely check the grounded plates, where as the charged plates will clean easily.

Fixing Cell Arcing

If a cell is sparking, determine the sparking area and removed cell to inspect closer. To see the sparking, you may need to look in through the blower compartment. See photo below.

To best see a sparking problem, cut an inspection hole in the duct. An inspection window can also be used to see when to clean.

A cell that is sparking randomly throughout is uncommon but could be caused by a film left behind from washing. If tobacco is not cleaned from a cell it can build up and cause random sparking. Diesel fumes can cause shorting problems and are not easily cleaned. High altitude can make the air cleaner more susceptible to sparking. The collector plates should be cleaned to the bare shiny metal (stained is okay).

We have seen continuous sparking (month+) burn away the high voltage contacts between the cells or at the power box. When one cell sparks it draws a surge of current from the other cell. The surge causes a spark at the contacts between the cells. A cell with a burnt contact may also have a sparking problem elsewhere. A cell plate that that has experienced excessive sparking can become loose. The plates are mounted on rods and the surges cause sparking to erode the plate around the rod. Check for loose plates.

View of the Collector Cells through the blower compartmentIf a cell is shorted and keeps the LED indicator from coming on, then inspect for damage. A dent across several plates causing them to touch would be a simple short to find. A dandling ionizing wire can cause a short.

Here our photo shows the view of the cells through the blower compartment. If necessary use a mirror to locate the continuous sparking.