Aprilaire AA-700

Aprilaire Fan Powered FlowThru Humidifier w/ Digital Humidistat 18 gpd
Price: $240.00
In Stock


  17 GPD 12 GPD 17 GPD 18 GPD

Aprilaire 700 flow-thru fan powered whole-house humidifier. The Model 700 humidifier is designed for use in large to mid-size homes. The 700 is best mounted in a vertical warm air flow. Before ordering please determine your mounting location and if there is adequate room for the model 700.

The Model 700 is a complete system and includes the humidifier, the water panel (#35), digital automatic humidistat (Model 60) with outdoor temperature sensor, self-piercing saddle valve, and 24vac transformer (#4010). Our photos (click View More Images above) for a view of all the items included. Items not included is the copper tubing, drain tubing, and thermostat wire.

Evaporative Capacity 0.75 gph
Unit Size 15-29/32W x 18H x 10-11/32D
Plenum Opening 14¾W x 14-5/16H
Electrical data 129 Vac, 60 Hz, 8/10 amp
When operating the water feed rate is 6 gph

Aprilaire 700 Series Parts
Aprilaire 35 Water Panel
NuCalgon Micro-Plus Treatment System
Aprilaire 700 Installation and Template (2 Pages, 1.1M pdf)Aprilaire Humidifier Owners and Operation Manual (11 Pages, 854k pdf)
Parts Drawing for Aprilaire 700 (2 Pages, 912k pdf)Aprilaire Selection Guide (1 Page, 85k pdf)
Aprilaire Humidifier Service, Repair, Maintenace Manual (26 Pages, 3.7M pdf)Aprilaire Humidifier Brochure Features (6 Pages, 534k pdf)
Aprilaire 60 Digital Humidistat Installation Manual (15 Pages, 1.3M pdf)Aprilaire 60 Digital Humidistat Owners and Operation Manual (7 Pages, 353k pdf)
Installation of Digital Humidistat (8 Minutes, 13M wmf)Relitive Humidity Defined (4 Pages,270k pdf)

Aprilaire 700 Mounting Location

The Aprilaire 700 should be mounted in the warm air flow or if mounted in the return duct, hot water is needed. The air flow should be vertical as the 700 draws air from the center and returns it out the sides. See Installation Instructions.

Aprilaire 700 Humidifier Return Duct Mounting Location 16 x 18 x 10-3/4

Aprilaire Model 60 Digital Humidistat

Aprilaire 60 Humidistat New FeaturesThe Aprilaire 500 operates best when the furnace blower is turned on.

The Model 60 digital humidistat can turn on your HVAC blower when there's no need for humidification or heat. It works in conjuction with your heating, ventilating, ait cinditioning equipment (HVAC) to control the operation of the humidifier.

A new feature of the Model 60 is a simple onboard switch for manual mode or automatic mode. Automatic mode adjusts the humidity based on the outdoor tempreature. This feature can be disabled by a click of a switch. The previous Aprilaire humidistats required installing a manual mode resitor (see the Model 60 Owners Manual).

What is a Flow-Thru Humidifier?

The term Flow-Thru refers to water trickling through the water panel and out a drain. The advantages of a flow-thru design is reduced maintenance and no standing water. Scale from calcium and lime gets flushed out of the water panel and down the drain. The water panel is an aluminum mesh with a porous pumice-like coating that inhibits growth of slime and is easy to change (once a year).

The disadvantage of the Flow-Thru is water usage. When in operation water flows in to the 700 water panel 6 gph. We are in the northeast where this is not an issue. We get a flat rate water bill unless there is excessive usage then the rate goes up. The Flow-Thru humidifier does not cause excessive usage.

The Flow-Thru is an evaporative humidifier and requires hot air. If not using hot air then hot water should be used. We see little humidity gain if our Flow-Thru humidifier is operating with cold air (and cold water). We run our blower on constant to best utilize our electronic air cleaner, but our humidifier is wired to only operate only when there is hot air and works very well.

Flow-thru Humidifier Type Demostration

By-Pass Versus Power Humidifier


By-pass Flow-Through Humidifier Demostration
Power Flow-Through Humidifier Demostration

The term By-Pass or Power refers to the driving force behind the air flow. The Power humidifier (aka Fan Power) uses a fan to draw the air thru the humidifier. The ByPass humidifier uses a 6" diameter duct that connects the supply to the return duct.

In the ByPass configuration the air leaving the furnace is routed back to the supply. The warm air leaving the furnace takes this short-cut of least resistance and bypasses the long trip down the duct work, in to the house, and back through the return. The ByPass is the 6" round duct work shown below. During the the hot humid A/C season the ByPass duct should be closed with the butterfly valve since the air flow through the humidifier would not be needed.

The Power humidifier uses a fan to draw air in from the duct and through the humidifier and exhausts back out in to the duct. The air is drawn in through duct at the center of the humidifier and back out in to the duct at the sides. The power humidifier should be mounted in vertical warm air flow.

The Model 400, 500, and 600 are ByPass humidifiers. The 700 is fan powered.

Manual Versus Automatic Humidistat

The indoor humidity level needs to be set based on the outside temperature. This is to prevent water from running down the windows. The cool air near the windows can not hold the humidity and water will condense on the glass. To prevent this condensation, the indoor humidity level is sacrificed by lowering the humidistat.

The automatic humidistat included with the Aprilaire 400 (Aprilaire 60) adjusts the humidity by using an outside temperature sensor.

The Aprilaire manual humidistat as used in earlier Aprilaire (Model 4655) requires adjusting the relative humidity based on the outside temperature. The chart below shows the humidity setting for a range of outside temperatures.

Aprilaire Humidity Information (270k pdf 4 Pages) Aprilaire 60 Digital Humidistat Installation (15 Pages, 1.3M pdf)
When The Outdoor
Temperature is
This Relative Humidity
Should Be Maintained
+40°F
45%
+30°
40%
+20°
35%
+10°
30%
25%
-10°
20%
-20°
15%

The New Aprilaire 700 Replaces 700A

In 2009 Aprilaire consolidated the Models 700M and 700A to the Model 700. The new Model 700 is identical to the earlier 700A, except the new 700 does not include a 2nd (#35) Water Panel and a DVD Video.

The difference between the 700A (automatic) and 700M (manual) was the 700M included a low cost manual humidistat (#4655) instead of the Automatic Digital humidistat (#58) that was included with the 700A.

The new 700 now includes the (Model #60) that can be operated as a Manual or Automatic humidistat.

Previous to the 700A & 700M was the Model 700 Series One. This early Model 700 was Cream in color whereas since the 700A & 700M (2008) the color has been a light Slate.

Aprilaire 700 Series Two Wiring - 2008 to Present

The Aprilaire model 700A, 700M and 700 manufactured in 2008 and later are Series Two and designed primarily for an automatic humidistat. To turn-on these units require a humidistat that sends 24v to the humidifier.
Aprilaire 700 Series 2 Wiring
The 700 series two has a controller relay (pn 4740) that turns on the fan when the humidistat sends 24v to the humidifier. The 24v is also routed to the solenoid valve. The diagram above shows the operation of this controller relay.

The operation of the series two controller relay is significantly different than that in the previous model 700. For simplicity the above diagram does not show the wiring to the humidistat necessary to sense when the furnace is running. Or the outdoor temperature sensor.

Aprilaire 700 Series One Wiring - Through 2008

The Aprilaire model 760, 768 and 700 manufactured before 2008 were Series One and originally designed for a manual humidistat. To turn-on the unit required a simple on-off switch type humidistat. An automatic humidistat was retrofitted.
Aprilaire 700 Series 1 Wiring
The 700 series one has a controller board (pn 4238) with a 24v transformer that powers the fan relay and solenoid valve. The diagram above shows the operation of this controller board.

The operation of the series one controller board is significantly different than that in the current model 700. For simplicity the above diagram does not show the wiring necessary to supply 120v only when the furnace is running. Or otherwise the addition of the model 50 current sensing relay.

Related Products

Aprilaire 35 Water Panel
35
Aprilaire Water Panel Pad Size 10x13x1½
Price: $12.00
Aprilaire 500 ByPass Flow-Thru Humidifier
500
Aprilaire 500 Humidifer with Digital Humidistat
Price: $156.00
Aprilaire 600 ByPass Flow-Thru Humidifier
600
Aprilaire 600 Humidifer with Digital Humidistat
Price: $168.00
Aprilaire 400 configured with the duct on the right side
400
Aprilaire 400 Humidifer with Digital Humidistat
Price: $188.00
HFT2999FP Fan Power Humidifer Included Items
HFT2900FP
White-Rodgers Power Flow-Thru Humidifier 19 gpd
Price: $225.00
HE365H8908 Honeywell Humidifier Includes These Items
HE365H8908
Honeywell Power FlowThru Humidifier w/H8908B 18 gpd
Price: $245.00
Search
Shopping Cart
Your cart is empty.
Browse Categories